How to Diagnose and Fix H6 Error Code on Goodman Furnaces

The H6 error code on Goodman furnaces indicates a specific safety or operational fault that requires prompt attention. This code commonly appears in modern Goodman furnace models with electronic control boards, helping homeowners and technicians quickly identify issues affecting the furnace’s performance. Understanding the meaning, causes, and troubleshooting methods for the H6 error can prevent prolonged system downtime and costly repairs.

Aspect Details
Meaning of H6 Code Pressure switch open or stuck
Common Causes Blocked vent, defective pressure switch, wiring issues
Recommended Fixes Inspect venting, replace pressure switch, check wiring
Safety Precautions Turn off power before servicing, use qualified technician if unsure

What Does the Goodman Furnace H6 Error Code Mean?

The H6 error code signals a problem with the pressure switch in Goodman furnaces. The pressure switch is a key safety component that ensures the proper venting of combustion gases before igniting the burners. The H6 code typically indicates that the pressure switch remains open or does not close as expected during the startup sequence, preventing the furnace from operating safely.

Common Causes of the H6 Error Code

Several underlying issues can cause the pressure switch to fail or stay open, triggering the H6 error code:

  • Blocked or Restricted Venting: Debris, bird nests, or ice buildup can obstruct the exhaust or intake vents, causing insufficient airflow or pressure differential.
  • Faulty Pressure Switch: The switch itself may malfunction due to age, corrosion, or internal wiring faults.
  • Disconnected or Damaged Tubing: A rubber hose connects the pressure switch to the draft inducer or vent system. If this hose is cracked, disconnected, or clogged, the pressure switch won’t operate properly.
  • Draft Inducer Fan Issues: The inducer motor might not be running as needed, causing inadequate pressure in the system.
  • Electrical Problems: Damaged wiring or loose electrical connections can interfere with the pressure switch signal.

Step-By-Step Troubleshooting for H6 Error Code

Troubleshooting the H6 code requires systematic checking of the furnace’s venting system and pressure components. Follow these steps carefully, ensuring power is off to avoid injury.

1. Inspect the Vent and Intake Pipes

Look for blockages such as leaves, snow, ice, or nests around the furnace’s vent pipes. Remove any visible obstructions and ensure pipes are securely attached without cracks or holes.

2. Examine the Pressure Switch Tubing

Locate the small tubing connected from the draft inducer to the pressure switch. Check for cracks, clogs, or disconnections. Replace damaged hoses for proper vacuum sensing.

3. Test the Draft Inducer Motor

Turn on the furnace and observe if the inducer motor starts running smoothly. A non-functioning inducer fan can prevent pressure buildup necessary to close the pressure switch.

Call 888-906-9139 for Free Local HVAC Quotes – No Obligation, Just Savings!

4. Check the Pressure Switch Functionality

If accessible, test the pressure switch with a multimeter to confirm if it opens and closes according to pressure changes. A faulty switch needs to be replaced by a professional.

5. Verify Electrical Connections

Inspect wiring for corrosion, breaks, or loose connectors around the pressure switch and control board. Repair or replace damaged wiring.

When to Call a Professional HVAC Technician

If basic troubleshooting fails to resolve the H6 error, or if the steps involve complex dismantling, it’s safest to call a licensed HVAC technician. Improper handling of furnace components can lead to safety hazards such as gas leaks or carbon monoxide exposure. Professionals have the experience and tools necessary to properly diagnose and repair pressure switch-related faults.

Preventing Future H6 Error Codes

Routine maintenance helps avoid issues leading to the H6 error code. Recommended maintenance practices include:

  • Regular inspection and cleaning of vent and intake pipes to prevent blockages.
  • Annual professional furnace tune-ups focusing on the inducer motor and pressure switch function.
  • Promptly addressing any unusual furnace behavior or error codes.
  • Ensuring proper installation and venting by qualified installers.

Goodman Furnace Error Code Overview

Error Code Common Cause Description
H6 Pressure switch stuck open Safety switch prevents ignition due to incorrect venting or switch failure.
H8 Pressure switch stuck closed Switch does not open properly, indicating a potential wiring or control board issue.
H10 Flame sensor error Failed flame sensor or dirty sensor prevents proper flame detection.