When a furnace blower won’t turn off, it can lead to uncomfortable indoor temperatures, increased energy bills, and potential damage to your heating system. This issue commonly arises due to electrical glitches, thermostat problems, or mechanical faults. Understanding the causes and remedies can help homeowners in the United States quickly resolve blower issues and maintain efficient furnace operation.
Common Causes | Symptoms | Possible Solutions |
---|---|---|
Thermostat Fan Setting | Blower runs continuously | Adjust fan setting to “Auto” |
Fan Limit Switch Malfunction | Blower won’t shut off even when furnace is off | Inspect and replace switch if faulty |
Relay or Control Board Issue | Intermittent or constant blower operation | Test and replace defective relay or control board |
Stuck Blower Relay | Blower won’t deactivate | Reset or replace stuck relay |
Wiring or Electrical Fault | Erratic blower behavior | Professional electrical troubleshooting required |
Common Reasons Why a Furnace Blower Keeps Running
The furnace blower keeps running due to several possible underlying issues. The most frequent cause is the thermostat fan setting being stuck on “On” instead of “Auto.” When set to “On”, the blower motor runs continuously to circulate air regardless of the furnace operation. Other causes include mechanical or electrical faults detected within the furnace control components.
Additionally, the fan limit switch plays a critical role by sensing when the furnace’s heat exchanger is hot enough to turn on the blower and turns it off when the air cools down. If this switch malfunctions or becomes stuck, the blower will not stop running.
Thermostat Fan Settings and Their Impact
The thermostat controls the furnace blower through the fan settings:
- Auto: The blower runs only when the furnace is heating. Once the desired temperature is reached, the blower shuts off.
- On: The blower runs continuously regardless of temperature.
If the thermostat fan is set to “On,” the blower will run non-stop causing high power consumption and possible wear. Switching the setting to “Auto” is the first step to resolve continuous blower operation. Confirming the thermostat wiring and calibration can also prevent persistent blower issues.
Fan Limit Switch: Function and Troubleshooting
The fan limit switch prevents the blower from running when the furnace is cold and ensures the blower starts only after the heat exchanger reaches an optimal temperature. It usually consists of a bimetal sensor and two settings controlling blower on/off and burner operation.
Common problems include:
Call 888-906-9139 for Free Local HVAC Quotes – No Obligation, Just Savings!
- Switch stuck in the “On” position: Causes blower to run continuously.
- Failure to detect temperature changes: Leads to improper blower cycling.
Testing or replacing the fan limit switch can help fix blower problems. This task is usually handled by a qualified HVAC technician due to safety considerations.
Diagnosing Relay and Control Board Issues
The furnace blower motor is controlled electrically through relays and the furnace control board. A stuck relay can cause the blower to stay on indefinitely. Similarly, if the control board malfunctions, it might send constant signals to run the blower motor.
Symptoms of relay or control board issues include intermittent blower operation, blower running without heat, or complete blower failure. Testing electrical components with a multimeter and visual inspection for burn marks or corrosion can identify faulty parts. Replacement of relays or control boards should be performed by professionals.
Electrical Wiring and Component Checks
Wiring faults such as short circuits or damaged wires can cause the blower motor to behave erratically, including running non-stop. Inspecting wiring harnesses for wear, loose connections, or corrosion is critical.
Other components like the blower motor capacitor or limit switch wiring can also affect blower operation. Ensuring proper electrical connections and component integrity helps prevent blower motor malfunctions.
Steps to Fix a Furnace Blower That Won’t Turn Off
Homeowners can follow these steps before calling a professional:
- Check the Thermostat Fan Setting: Locate the fan setting on your thermostat and switch it from “On” to “Auto.”
- Reset the Furnace: Turn off power to the furnace for a few minutes and turn it back on to reset control systems.
- Inspect Air Filter and Vents: Ensure blockage-free air circulation as restricted airflow can cause blower issues.
- Check for Obvious Damage: Inspect wires, switches, and relays for visible damage or loose connections.
- Call a Licensed HVAC Technician: For in-depth electrical diagnostics, switch replacement, and motor repairs.
Preventive Maintenance to Avoid Blower Issues
Regular maintenance can extend the life of furnace components and prevent blower problems:
Call 888-906-9139 for Free Local HVAC Quotes – No Obligation, Just Savings!
- Change air filters every 1-3 months to maintain proper airflow.
- Schedule annual HVAC inspections to identify mechanical or electrical issues early.
- Keep thermostat batteries fresh and replace aging thermostats.
- Ensure vent and ductwork are clear and free of obstructions.
- Lubricate motor bearings if applicable, per manufacturer instructions.
When to Call Professional Furnace Repair Services
If DIY checks do not resolve the blower running problem, it is essential to contact licensed HVAC professionals. Complex issues like:
- Faulty fan limit switches
- Blower motor malfunctions
- Control board or relay replacements
- Electrical wiring repairs
require expert diagnosis and repair. Attempting such repairs without experience can risk damage or personal injury. Professional technicians provide safe, reliable service ensuring your furnace blower functions as intended.