Tempstar Furnace Blinking Green Light: Causes, Troubleshooting, and Solutions

tempstar furnace blinking green light

Tempstar furnaces are known for their reliability and efficiency. However, when the green light on a Tempstar furnace blinks, it signals a specific status or issue within the system. Understanding what a blinking green light means is critical to ensuring the furnace operates safely and effectively. This article explores the common causes behind a blinking green light on a Tempstar furnace, troubleshooting steps, and practical solutions for homeowners and HVAC professionals.

Green Light Behavior Meaning Common Causes Suggested Action
Slow blinking Normal operation/standby Furnace waiting for thermostat signal No action needed
Fast blinking Diagnostic error code Ignition failure, flame sensor issues, limit switch open Troubleshoot specific error codes in manual
Continuous blinking with no heat System fault Electrical fault, blower motor problems Contact HVAC technician

What Does a Blinking Green Light Mean on a Tempstar Furnace?

The green light on a Tempstar furnace serves as a status indicator. A continuously lit green light usually means the furnace is functioning correctly. However, when the green light blinks, it conveys specific messages regarding the furnace’s operational state.

Slow blinking often indicates that the furnace is in standby mode, waiting for the thermostat to call for heat. This is typically normal behavior.

Rapid blinking usually appears when the furnace detects a fault or error. These blink codes correlate with diagnostic messages that point to an internal problem such as ignition failure or sensor malfunctions.

Common Reasons for a Tempstar Furnace Green Light Blinking

Ignition Failure

An ignition failure is one of the most frequent reasons for a blinking green light. The furnace attempts to ignite the burner but fails due to issues like a dirty ignitor, faulty flame sensor, or insufficient gas supply.

Flame Sensor Problems

The flame sensor ensures the burner flame is present. If it becomes coated with debris or is malfunctioning, the furnace may shut down for safety and cause the green light to blink rapidly.

Limit Switch or Pressure Switch Faults

Safety switches such as the limit switch or pressure switch monitor the furnace operation. If these switches detect unsafe conditions, the furnace will shut off and signal an error with a blinking light.

Call 888-906-9139 for Free Local HVAC Quotes – No Obligation, Just Savings!

Electrical or Control Board Issues

Faults in the electrical system or the control board may cause blinking lights. These defects can arise from wiring problems, power surges, or component failures.

How to Interpret Tempstar Furnace Blink Codes

Tempstar furnaces use the green light’s blinking pattern as error codes. The number of blinks corresponds to a specific issue:

  • 1 Blink: Pressure switch error
  • 2 Blinks: Pressure switch stuck closed
  • 3 Blinks: Pressure switch stuck open
  • 4 Blinks: Ignition failed
  • 5 Blinks: Flame sensed when there shouldn’t be
  • 6 Blinks: Limit switch tripped
  • 7 Blinks: Blower motor issue
  • 8 Blinks: Fan control relay stuck

Refer to your Tempstar furnace owner’s manual to match blinking sequences precisely to diagnose the issue.

Troubleshooting Steps for Blinking Green Light on Tempstar Furnace

Step 1: Check the Thermostat

Confirm the thermostat is set to “heat” and at a temperature higher than the current room temperature. Incorrect settings can cause the furnace to remain in standby, resulting in slow blinking.

Step 2: Inspect the Furnace Filter

A clogged air filter restricts airflow and triggers safety shutoffs. Replace or clean filters regularly to prevent furnace errors.

Step 3: Reset the Furnace

Turn off power to the furnace, wait five minutes, and switch it back on. This sometimes clears electronic glitches and resets error codes.

Step 4: Examine the Flame Sensor

Gently clean the flame sensor rod with fine sandpaper or steel wool. Avoid damaging the sensor, as dirty sensors often cause ignition lockouts.

Call 888-906-9139 for Free Local HVAC Quotes – No Obligation, Just Savings!

Step 5: Check for Obstructions and Venting Issues

Ensure vents and exhaust pipes are clear of blockages. Proper airflow is crucial for safe furnace operation.

When to Call a Professional HVAC Technician

While basic troubleshooting helps with minor issues, certain conditions require expert attention. If the green light blinks rapidly and persists despite resets, or if the furnace does not produce heat, professional service is recommended to diagnose complex electrical or gas system problems safely.

Faulty ignition systems, malfunctioning control boards, and gas supply problems must be handled by licensed technicians. Attempting repair without experience can be dangerous.

Maintaining Your Tempstar Furnace to Prevent Issues

  • Regular Maintenance: Schedule annual HVAC inspections to catch early signs of wear or failure.
  • Clean or Replace Filters Monthly: Ensures optimal airflow and prevents overheating.
  • Keep Vents Clear: Remove debris and obstructions around intake and exhaust vents.
  • Monitor the Thermostat: Use programmable thermostats to reduce unnecessary furnace cycles.

Understanding Tempstar Furnace Indicator Lights

Besides the green light, Tempstar furnaces may also have red or amber lights indicating warnings or critical errors. The green light blinking pattern, however, remains a primary diagnostic tool. Always refer to the user manual for detailed light code charts tailored to your specific furnace model.

Scroll to Top